Products

Air Cooled Scroll Packaged Unit APCA


From 18.5 to 246 kw


 The Armanik APCA large series are air cooled packaged unit for cooling / heating applications and outdoor installation.They are available in 13 models with nominal cooling capacities ranging from 18.5 to 246 Kw

These series are ideal for supplying conditioned air for industrial applications and process cooling / heating. 


Air Cooled Scroll Packaged Unit APCA
►     Optimized design for R407c refrigerant
►     Fast and easy installation.
►     Highly configurable.
►     Casing: Galvanized steel plate with polyesteric coating. 
►     Assembly: Fully bolted/welding free. 
►     Compressor: High-efficiency scroll compressors are quiet and more reliable 
►     Air heat exchanger: Cross fin coil Internally grooved copper tubes and louvered aluminum fins,Direct drive propeller .
►     Fan: Low rpm, quiet operation. 
►     Air heat exchanger: Cross finned coil - copper tubes / aluninum fins Dx type. 
►     Blower: Centrifugal double inlet -forward curved. 
►     Evaporator Casing : Double skin with  50 kg/m³ rock wool insulation
►     Air filter : Aluminium mesh filter (G2) & rigid bag filter(F7)
►     Factory fitted accessories: 
 
- High/low pressure switch.
- Suction & Discharge compressor shut-off valve
- Phase sequence- phase failure - reverse phase and voltage monitoring device.
- Evaporator low temperature protection.
- Electronic microprocessor control with digital display.
- Differential air pressure switch.
- High and low pressure transmitters.
- High pressure safety valve on compressor discharge.
- Constant compressor current monitoring control.
- Compressor inside module protection.
- Low and high pressure gauges for each cooling circuit.
- Oil sump heater.
- Frequency inverter for condenser's fan operation.
- Thermostatic expansion valve, ensuring constant suction gas superheat, at all operating conditions.
- BMS interface kit for Mod bus connection.
- Pad type anti-vibrations.
►     Optional accessories :
 
- Unit with 100% redundant compressors.
- R134-a refrigerant available.
- Unit with fully inverter compressors.
- Unit with remote condensers.
- Unit with low noise operations.
- Unit with super low noise operations.
- Unit with EC fans for condenser or evaporator.
-Unit with plug fan or backward curved impeller.
- Unit with return fan.
- Plate or wheel heat recovery are available.
- Unit with electronic expansion valve .
- Star-delta start type for reducing starting current.
- Additional oil separator.
- Liquid receivers, muffler, suction accumulator.
- Microchannel condensing coil.
- Fully PLC based control.
- Touch screen monitoring.
- Power multimeter and Forced limit of power consumption.
- Soft starter.
- Hygienic models are avialable.
-High efficiency air side filteration such HEPA , active carbon ,chemical filter are avialable.
- Bottom compartment protection nets.
- Coil protection nets.
-Unit with electrical , hot water or steam coil if heating required.
- Evaporator antifreeze heater and heat recovery exchangers if applicable.
- Digital input for double set-point.
- Remote set-point.
- Compressor in-line suction filter.
- 4-20 mA or 0-10 Volt analogue signal for shifting set-point.
- Copper/pre-painted (blue or gold) aluminum fin or copper/copper coils.
- Blygold, Heresite or Sakaphen coating for condensing coil.
- Interfaces for serial communication with other devices.
- Integrated management of multiple unit.
- Spring anti-vibration mounts.
- Condensing coil and fan's enclosure for un-operation season.
- Centrifugal Fans for condenser in special operations.
APCA 05-70  
Type   APCA-05 APCA - 08 APCA - 012 APCA - 014 APCA - 16 APCA - 18 APCA - 23 APCA - 27 APCA -32 APCA - 37 APCA - 46 APCA -54 APCA -70
Nominal Cooling capacity Kw 18.5 28.7 41.0 50.1 55.9 65.5 82.0 95.7 111.7 131.0 163.9 191.3 246.3
  RT 5.3 8.2 11.7 14.2 15.9 18.6 23.3 27.2 31.8 37.2 46.6 54.4 70.0
  Btu/h 63,115 97,913 139,876 170,921 190,708 223,460 279,751 326,490 381,076 446,920 559,161 652,639 840,277
Construction Material /Color Galvanized steel / Dark Grey (Ral7034)
Panels Insulation Material 50mm Injected Polyurethane - Double Wall Panels- Aluminium Frames
Compressor Scroll
Quantity   1 1 1 2 2 2 4 4 4 6 6 6 8
Capacity Steps Liner
Absorbed power Kw 4.7 6.9 10.4 12.6 13.8 16.0 20.8 24.8 27.6 32.0 41.6 49.6 65.2
Nominal Operating Current A 8.4 12.9 19.0 24.0 25.8 29.6 38.0 49.8 51.6 59.2 76.0 99.6 111.0
Maximum Operating Current A 12.1 20.0 27.0 34.0 40.0 44.0 54.0 64.0 80.0 88.0 108.0 128.0 160.0
Crankcase Heater Power W 70 70 70 140 140 140 140 140 280 280 280 280 280
Electrical characteristics 400V/3Ph/50Hz
Condenser High capacity cross finned coil with internally grooved tubes and aluminum fins
Condenser Fans Type Axial
Quantity   1 1 1 2 4 4 4 4 4 4 4 4 6
Total Air Flow M³/h 8500 11900 11900 23800 47600 47600 47600 81600 81600 81600 81600 81600 122400
Speed Rpm 900
Absorbed Power Kw 0.51 0.77 1.13 2.26 4.52 4.52 4.52 7.4 7.4 7.4 7.4 7.4 11.1
Nominal Operating Current A 0.9 1.5 2.2 4.6 9.2 9.2 9.2 14.6 14.6 14.6 14.6 14.6 21.9
Maximum Operating Current A 0.9 1.5 2.3 4.6 9.2 9.2 9.2 14.6 14.6 14.6 14.6 14.6 21.9
Evaporator Cross Finned Coil - Copper Tubes / Aluninum Fins
Face Area 0.45 0.67 0.865 1.07 1.31 1.4 1.8 2.15 2.51 2.78 3.31 3.58 3.58
Rows   4 4 4 4 4 4 4 4 4 4 4 4 6
Evaporator Fans Type Centrifugal Double Inlet -Forward Curved
Quantity   1 2 2 2 2 2 2 2 2 2 1 1 1
Discharge air direction Regarding To The Client Request
Nominal Air Flow   3300 5800 7700 9100 11250 12800 15500 19400 22340 26200 30000 34000 38000
Speed R.P.M 1014 867 714 732 611 621 750 637 641 655 668 640 684
Absorbed Power Kw 0.7 1.2 1.9 2.0 2.4 3.2 3.3 4.3 4.5 6.1 6.2 7.6 9.1
Available External Static Pressure Pa 100
Type Of Drive Tappered bush pulleys - V belts
Fan Motor Type Squirrel Case TEFC - Insulation Class F / IP-55
Installed Power Kw 1.1 2.2 3.0 3.0 4.0 4.0 4.0 5.5 5.5 7.5 7.5 11.0 11.0
Speed R.P.M 1450 1450 1450 1450 1450 1450 1450 1450 1450 1450 1450 1450 1450
Nominal Operating Current A 1.6 3.3 3.4 3.5 5.7 5.7 5.7 7.8 7.8 10.4 10.4 14.5 14.5
Maximum Operating Current A 2.3 4.7 6.3 6.3 8.2 8.2 8.2 11.1 11.1 14.9 14.9 20.7 20.7
Electrical characteristics 400V/3Ph/50Hz
Total Absorbed Power Kw 6.3 9.9 14.5 17.9 22.3 24.5 29.3 37.7 40.5 46.9 56.5 68.0 87.3
Total Nominal Operating Current A 10.9 17.7 24.6 32.1 40.7 44.5 52.9 72.2 74 84.2 101 128.7 147.4
Total Maximum Operating Current A 15.3 26.2 35.6 44.9 57.4 61.4 71.4 89.7 105.7 117.5 137.5 163.3 202.6
Power Cables Cross Section Per Phase mm2 6 10 16 16 16 25 25 35 50 70 95 120 150
Fuses A 3x25 3x32 3x40 3x50 3x63 3x63 3x80 3X100 3X125 3X125 3X160 3X200 3X250
Voltage Operating Limits V 360-440V
Refrigerant Circuit    
Number Of Circuits   1 1 1 2 2 2 2 2 2 3 3 3 4
Expansion Device Thermostatic Expansion Valve
Refrigerant Type R407-C
Air Filter Type Aluminium Mesh Filter (G2) & Rigid Bag Filter(F7)
Sound Level At 3m dbA 57 59 59 62 62 62 66 66 66 68 68 68 70
Dimensions Width (mm) 1,324 1,324 1,630 1,936 1,936 1,936 1,936 2,098 2,098 2,098 2,098 2,098 2,098
  Length (mm) 3,789 3,789 3,942 4,095 4,095 4,248 4,707 5,260 5,260 6,331 7,596 7,596 8,514
  Height (mm) 1,464 1,464 1,464 1,617 1,923 1,923 1,923 2,149 2,149 2,402 2,402 2,402 2,402
Shiping Weight Kg 1,201 1,201 1,271 1,333 1,500 1,774 2,075 2,622 3,139 3,279 3,686 4,134 4,428

Notes
1.  Validity af above capacities : Summer 27 °C db/ 19 °C wb an coil/ 35 °C ambient, Winter 20 °C on coil 7 °C db/ 80% rh ambient

2. Limits of operation Ambient -5 °C / 45 °C. Nominal air flow+- 10% .

3.  Given cables cross sections are only indicative and have been calculated for 40°C ambient Always consult local regulations.

4. Units are shipped factory wired, charged and run tested.

5.Leave at least 1,5 m of distance from condenser inlet(s) and 2 m above condenser fans discharge.

6. Options like mixing boxes, return fans, hot water or electric heating coils are not included in the standard version, Always consult the manufacturer for such options,including external static other than 100 pa.